air to air heat exchanger for HVAC system
Introduction
Shanghai Shenglin M&E Technology Co.,Ltd
is the professional manufacturer of air to air heat exchanger,heat exchanger core,air ventilator,ventilation systems and heat product.
Specifications
Heat recovery industry air ventilator1.Air volume:6000m3/h
2.Static pressure:250Pa
3.Efficiency:76%
4.Input power:4158W
Heat recovery industry air ventilators
Product description:
H Series Heat Recovery industry air Ventilator built-in highly efficient heat exchanger, so that the return air and supply air can realize sensible heat exchange and latent heat exchanger during the air flow on the plate, not only provides a comfortable temperature, but also recover and save the energy.


Specification | |||
Model Number | H-02DZ | ||
Grade | High | Medium | Low |
Air volume (m³/H) | 200 | 150 | 120 |
Rated voltage | 220 V | ||
ESP Pa | 75 | 60 | 60 |
Power consumption | 68 | 63 | 60 |
Temp efficiency | 57% | 60% | 63% |
Noise (dBA) | 30 | 29 | 28 |
Dimension mm | 828*500*282 | ||
Weight kg | 32 |
Features:
1.Energy Saving
Crossflow energy recovery unit, use patent technology, improved the energy recovery efficiency, reduced the air flow resistance
2.Application Range
Air flow 4000~16000m3/h, suitable for meeting room, office, machine room and industrial occasions which contains stink, dust, bacteria, viruses.
3.Convenient Installation
Unit ground installation, placed in the base of the smooth, on the ceiling space meet the conditions set can also be installed in the ceiling, a bottom channel base, more safety. Tuyere is diversiform, can according to the customer request design, ease of installation.
4.Low Noise
Optimized structure design, used sound-absorbing material and nonmetallic impeller, guaranteed the good static sound effect.
5.Complete Function
Two-way air exchange, air purification, energy recovery and so on, easy to control.
Performance Parameter:
Model | Air Volume(m3/h) | Static Pressure(Pa) | Volts/Hz | Motor Power (Kw) | Temperature Efficiency (%) | Noise [dB(A)] | Dimension (mm) | Re. Weight (kg) |
H-02D | 200 | 40 | 220V-1-50Hz | 0.016*2 | 77 | 30 | 665x580x293 | 30 |
H-03D | 300 | 50 | 220V-1-50Hz | 0.03*2 | 77 | 32 | 745x600x293 | 35 |
H-04D | 400 | 55 | 220V-1-50Hz | 0.04*2 | 78 | 34 | 745x800x293 | 42 |
H-06D | 600 | 110 | 220V-1-50Hz | 0.15*2 | 76 | 35 | 820x900x293 | 50 |
H-08D | 800 | 110 | 220V-1-50Hz | 0.15*2 | 76 | 37 | 1110x880x413 | 76 |
H-10D | 1000 | 130 | 220V-1-50Hz | 0.20*2 | 75 | 38 | 1110x1135x413 | 96 |
H-16D | 1500 | 150 | 380V-3-50Hz | 0.37*2 | 73 | 48 | 1350x940x500 | 142 |
H-20D | 2000 | 150 | 380V-3-50Hz | 0.45*2 | 73 | 53 | 1460x1020x500 | 166 |
H-25D | 2500 | 160 | 380V-3-50Hz | 0.55*2 | 74 | 56 | 1460x1020x600 | 182 |
H-30D | 3000 | 190 | 380V-3-50Hz | 0.80*2 | 74 | 59 | 1600x1100x540 | 196 |
H-35D | 3500 | 100 | 380V-3-50Hz | 2345 | 70 | 61 | 1600X1100X620 | 230 |
H-40D | 4000 | 210 | 380V-3-50Hz | 1.00*2 | 75 | 62 | 1750X1210X600 | 260 |
H-55D | 5000 | 210 | 380V-3-50Hz | 1.80*2 | 75 | 65 | 1800X1210X760 | 330 |
H-60D | 6000 | 240 | 380V-3-50Hz | 1.80*2 | 76 | 66 | 1850X1210X900 | 370 |



1. Services for 24 hours a day.
2. OEM&ODM available.
Note: for further information please contact me.